{"id":849,"date":"2018-09-25T07:56:03","date_gmt":"2018-09-25T07:56:03","guid":{"rendered":"http:\/\/www.buildinglift.com\/?p=849"},"modified":"2026-06-23T23:22:33","modified_gmt":"2026-06-24T07:22:33","slug":"torre-grua-mastil-seccion-ancla","status":"publish","type":"post","link":"https:\/\/www.buildinglift.com\/es\/torre-grua-mastil-seccion-ancla\/","title":{"rendered":"Tower Crane Mast Section and Wall Anchor"},"content":{"rendered":"<h2>Tower Crane Mast Section and Wall Anchor<\/h2>\n<p>The <strong>tower crane mast section and wall anchor<\/strong> work as parts of an engineered tower system. Mast type, free-standing height, tie spacing, anchor forces and building connection details must be reviewed for the specific crane and project.<\/p>\n<h3>Descripci\u00f3n<\/h3>\n<hr \/>\n<p>Mast section is composed of standard jointswhich are formed by group welded of angle steels with the structure of long square space trusses.<\/p>\n<h3>Features<\/h3>\n<hr \/>\n<p>Dimension ofmastsection:<br \/>\n1.5m*1.5m*2.2m for QTZ50 4808\/4810\/5008;<br \/>\n1.606*1.606*2.5 for QTZ63 TC5012;<br \/>\n1615m*1.615m*2.5m for QTZ60 TC5010\/QTZ63 TC5010;<br \/>\n1.68m*1.68m*2.5m for QTZ63 TC5013;<br \/>\n1.8m*1.8m*2.8m for QTZ63 TC5610\/QTZ80 TC6010;<br \/>\n1.835m*1.835m*2.5m for QTZ80 TC5513\/QTZ100 TC6010\/QTZ125 TC6515;<br \/>\n2.0m*2.0m*3m for QTZ315 TC7040 tower crane;<\/p>\n<table>\n<tbody>\n<tr>\n<td>Item<\/td>\n<td colspan=\"2\">\u00a0parameters<\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>Max.\u00a0load<\/td>\n<td>5t<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Jib\u00a0length<\/td>\n<td>50m<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Tip\u00a0load<\/td>\n<td>1.0t<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Free\u00a0standing\u00a0height<\/td>\n<td>40\u00a0m<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Max.\u00a0height<\/td>\n<td>150m<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Size\u00a0of\u00a0mast\u00a0section<\/td>\n<td>1.6\u00d71.6\u00d72.5<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Material\u00a0of\u00a0mast\u00a0section<\/td>\n<td>\u2220125\u00d7125\u00d710\u00a0buckled\u00a0square\u00a0steel\u00a0stiffened\u00a0plate<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Application<\/h3>\n<hr \/>\n<p>Automatic impeller blasting and spraying assembly line\uff1b<br \/>\nThe company adopts the world first-class automatic spraying assembly line\uff1b<br \/>\nThe large structure parts are dealt with impeller blasting before spraying\uff1b<br \/>\nThat effectively removes steel surface oxides and welding spatters, eliminates the internal stress in welding process, increases the parts&#8217; anti-fatigue strength<br \/>\nand steel surface hardness, and increases painting adhesion\uff1b<br \/>\nso that it prolongs the service life of the product, maximizes efficiency, and saves energy.<\/p>\n<h3>Parameter<\/h3>\n<hr \/>\n<p>Mast section is composed of standard joints which are formed by group welded of angle steels with the structure of long square space trusses.<br \/>\nEvery two standard joints of tower body are connected firmly by Level 10.9 M27 high-strength bolts and screws. Inside each standard joint there is a ladder with the same length so as to facilitate manipulation and maintenance personnel getting on and off tower crane.<br \/>\nThere is one rest platform every three joints. All standard joints have interchangeability. By changing the number of tower body standard joints installed, the crane will reach different lifting heights.<br \/>\nTwo groovy footsteps are welded respectively on two main chords on the same side of standard joints. This position of main chords has been strengthened.<br \/>\nWhile doing jack-up work, with the expansion of jack-up cylinder, shaft heads at two ends of jack-up beams and climbing claws of jack-up set frame fall into the footstep groove successively according to the procedure, so as to make jack-up set frame elevate vertically along with tower body.<\/p>\n<h2>Wall Anchorage Project Data<\/h2>\n<ul>\n<li>Crane model, tower type and planned height<\/li>\n<li>Manufacturer&#8217;s permitted tie levels and reactions<\/li>\n<li>Building structural drawings and anchor location<\/li>\n<li>Tie frame geometry and connection details<\/li>\n<\/ul>\n<p>Browse the <a href=\"https:\/\/www.buildinglift.com\/products\/tower-crane-mast-sectionanchor\/\">tower crane mast and anchor category<\/a> or <a href=\"https:\/\/www.buildinglift.com\/contact-us\/\">send the crane and building drawings<\/a>. Wall anchorage must be approved by qualified engineers for the actual site loads.<\/p>\n<p>For site planning, also review the applicable local rules and the <a href=\"https:\/\/www.hse.gov.uk\/construction\/safetytopics\/lifting-operations.htm\" target=\"_blank\" rel=\"noopener\">HSE lifting-operation guidance<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Tower crane mast section and wall anchor overview covering compatibility, tie spacing, connection details and project engineering requirements.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[17],"tags":[],"class_list":["post-849","post","type-post","status-publish","format-standard","hentry","category-tower-crane-mast-sectionanchor"],"_links":{"self":[{"href":"https:\/\/www.buildinglift.com\/es\/wp-json\/wp\/v2\/posts\/849","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.buildinglift.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.buildinglift.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.buildinglift.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.buildinglift.com\/es\/wp-json\/wp\/v2\/comments?post=849"}],"version-history":[{"count":4,"href":"https:\/\/www.buildinglift.com\/es\/wp-json\/wp\/v2\/posts\/849\/revisions"}],"predecessor-version":[{"id":7351,"href":"https:\/\/www.buildinglift.com\/es\/wp-json\/wp\/v2\/posts\/849\/revisions\/7351"}],"wp:attachment":[{"href":"https:\/\/www.buildinglift.com\/es\/wp-json\/wp\/v2\/media?parent=849"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.buildinglift.com\/es\/wp-json\/wp\/v2\/categories?post=849"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.buildinglift.com\/es\/wp-json\/wp\/v2\/tags?post=849"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}